| Sound insulation |
| Pod is leaking sound. | A gap between back glasses. | Push the glasses
together. |
| A gap between side frame seal and threshold seal. | Replace the seals. |
| The seal between the frontside glasses and frames is too
short. | Stretch the seal and reinstall it. |
| Floor of the pod is not level. | Level the floor. |
| Pod is not standing straight. | Straighten the
pod. |
| Door |
| Door is difficult to close | Seals are on the wrong side. | Remove the seals and install them on the inside of the
pod. |
| Side frame seal and threshold seal overlap. | Cut the threshold seal to the correct length. |
| Threshold installed too far out. | Reinstall the floor
threshold. |
| Floor of the pod is not level. | Level the
floor. |
| Pod is not standing straight. | Straighten the
pod. |
| No adjustment plate under the lower hinge. | Install an adjustment plate under the lower
hinge. |
| Power issues |
| No electricity in the pod. | Pod power cord not connected. | Check that the pod power cord is connected to a power
outlet. |
| Pod power cord is connected to a faulty power
outlet. | Connect the pod power cord to another power
outlet. |
| Loose connections under the floor cover board. | Check
connections under the floor cover board. |
| ON/OFF switch of the power unit is in the "O" position. | Turn the ON/OFF switch in the "I" position. |
| Power outlet not working. | Power outlet cord not connected. | Check
connection to power unit. |
| Fans and light |
| Fans and light do not switch on. | Faulty motion detector. See Diagnose a faulty motion detector. | Contact Framery Framery support for a replacement part. |
| Loose connections in the control unit. | Check
connections to control unit. |
| Loose connections under the floor cover board. | Check
connections under the floor cover board. |
| Light not working. | Light cord not connected to control unit. | Check
connections to control unit. |
| Fans not working. | Fan cord not connected to control unit. | Check
connections to control unit. |
| Fan modules' connections are loose. | Check fan modules'
connections. |
| Noisy fans. | Fan blades are obstructed. | Check that
fan blades can move freely. |
| Fan speed set to 100%. | Reduce the fan
speed. |
| Air inside the pod is not fresh. | Pod is positioned in direct sunlight, under a heating duct, or close
to some other heat source. Or, there is not enough space around or above
the pod. See Operating space. | (For pods equipped with the casters.) Move the pod to another
location. |
| Top of turnable table is loose. | Screw under tabletop is loose. | Reinstall the
screw. |