Level the floor

  1. Measure the floor with a spirit level at six measuring points:
    • On the ABS strips at the edges of the floor modules
    • Along the sides.
    If the floor is not level, complete the following steps.
  2. Take out the seats.
  3. Unscrew the 5x30 screws (2 pcs) and remove the floor grid.
  4. Unscrew the 5x50 screws (2 pcs) and remove the floor threshold.
  5. Pull the carpet out from under the wall felts and remove it from the pod.
  6. Use a 4 mm hex key or a 6 to 7 mm flathead screwdriver to screw the feet of the leveling screws (8 pcs) out or in. Measure opposite points repeatedly and adjust the feet of the leveling screws gradually. You can also use a flat head screw driver.
  7. Reinstall the removed parts.