Framery O Troubleshooting

Issue Cause Solution
Sound insulation
Door is leaking sound. Pod is not standing straight. Level the floor.
Door is too low. Adjust the door height.
Door seal is loose. Reinstall the door seal
Door is bent outwards from the top and bottom. Flip the bent door upside down
Power issues
No electricity in the pod. Pod power cord not connected. Check that the pod power cord is connected to a power outlet.
Pod power cord is connected to a faulty power outlet. Connect the pod power cord to another power outlet.
Power cord not connected to power unit. Check that the power cord is connected to the power unit
Tripped fuse. Reset the fuse
Power outlet not working. Power outlet cord not connected. Check the power outlet cord connection
Fans and light
Fans and light do not switch on. Faulty motion detector. See Diagnose a faulty motion sensor. Contact Framery Framery support for a replacement part.
Loose connections. Check all the electrical connections
DC cords are disconnected. Check the connection between the roof module and wall module DC cords
Light not working. Light cord not connected to control unit. Check that the light cord is connected to the control unit
Light's connections are loose. Check the light's electrical connections (pull out the light from the ceiling)
DC cords are disconnected. Check the connection between the roof module and wall module DC cords
Fans not working. Fan cord not connnected to control unit. Check that the fan cord is connected to the control unit
Fan module's connections are loose. Check the fan module's electrical connections
DC cords are disconnected. Check the connection between the roof module and wall module DC cords
Ventilation is at maximum level all the time. DC cord is broken. Contact Framery Framery support for a replacement part.
Noisy fans. Fan blades are obstructed. Check that fan blades can move freely.
Fan speed set to 100%. Adjust the fan speed
Air inside the pod is not fresh. Pod is positioned in direct sunlight, under a heating duct, or close to some other heat source. Or, there is not enough space around or above the pod. See Operating space. Move the pod to another location.