Install the cease fire

  1. Place the cease fire unit on the roof and mark the location for the mounting bracket.
    Make sure that the cease fire unit is straight (the distance from both ends of the unit to the edge of the roof body cover is the same).
  2. Install the mounting bracket onto the roof.
    Note:
    To avoid damaging the roof, do not use the screws that come with the cease fire package. Use shorter screws with a maximum length of 15 mm (0.6 in).
  3. Guide the piping into the hole in the roof and place the cylinder onto the mounting bracket. Tighten the rubber bands around the cylinder and secure them in place.
  4. Guide the rubber seal around the piping and attach the seal onto the roof body cover around the hole.
    Peel off the backing paper of the seal before attaching it.
  5. Install the sprinkler head to the ceiling.
  6. Install the sprinkler cover to the ceiling.