Install a fire alarm notification device (strobe, strobe-horn, speaker, speaker-strobe) (older pods with no junction box)

The instructions in this section only apply to pods that do not have a junction box.

DANGER:
Always disconnect the pod from the power outlet before you begin disassembly, maintenance, moving, or any other procedure.
  1. Remove the fan cover.
    Figure 1. * = With optional activated carbon filter
  2. Remove the plastic trims.
  3. Remove the roof body cover.
  4. Punch out the precut flap on the roof. Use a screwdriver.
  5. Cut away the acoustic material. Use a utility knife or a hole saw.
    Note:
    Do not cut through the roof.
  6. Cut away the second flap on the roof under the acoustic material. Use side cutters or a drill.
  7. Remove the flap.
    Note:
    If you cannot remove the flap from outside, remove it from the roof from inside.
  8. Use a longer drill bit or anything sharp to punch through from the middle of the hole to the ceiling panel. Cut away the required area from the ceiling panel with a utility knife. Use the base of the wired alarm device as reference.
  9. Install the base of the wired alarm device to the ceiling panel with two screws.
  10. Push the power cord of the wired alarm device through the hole to the roof.
  11. Install the alarm device to the base. Follow the manufacturer's instructions.
  12. Route the cord through the cable clamp and strain relief.
  13. Install the roof body cover.
    Note:
    Guide the cord of the alarm device out of the cut in the body cover. Make sure that the cord is not damaged during the installation.
  14. Install the plastic trims.
  15. Install the fan cover.
    Figure 2. * = With optional activated carbon filter