Install a fire alarm notification device (strobe, strobe-horn, speaker, speaker-strobe) (older pods with no junction box)
The instructions in this section only apply to pods that do not have a junction box.
DANGER:
Always disconnect
the pod from the power outlet before you begin disassembly, maintenance, moving,
or any other procedure.
-
Remove the fan cover.
Figure 1. * = With optional activated carbon filter -
Remove the plastic trims.
-
Remove the roof body cover.
-
Punch out the precut flap on the roof. Use a
screwdriver.
-
Cut away the acoustic material. Use a utility
knife or a hole saw.
Note:Do not cut through the roof.
-
Cut away the second flap on the roof under the
acoustic material. Use side cutters or a drill.
-
Remove the flap.
Note:If you cannot remove the flap from outside, remove it from the roof from inside.
-
Use a longer drill bit or anything sharp to punch
through from the middle of the hole to the ceiling panel. Cut away the required
area from the ceiling panel with a utility knife. Use the base of the wired
alarm device as reference.
-
Install the base of the wired alarm device to the
ceiling panel with two screws.
- Push the power cord of the wired alarm device through the hole to the roof.
-
Install the alarm device to the base. Follow the
manufacturer's instructions.
-
Route the cord through the cable clamp and strain
relief.
-
Install the roof body cover.
Note:Guide the cord of the alarm device out of the cut in the body cover. Make sure that the cord is not damaged during the installation.
-
Install the plastic trims.
-
Install the fan cover.
Figure 2. * = With optional activated carbon filter