Install a fire suppression device (sprinkler / cease fire)
DANGER:
Always disconnect the
pod from the power outlet before you begin disassembly, maintenance, moving, or any
other procedure.
-
Remove the fan cover.
Figure 1. * = With optional activated carbon filter -
Remove the plastic trims.
-
Remove the roof body cover.
-
Remove the precut flap from the roof.
-
Cut an "X" shape into the acoustic material.
-
Drill a hole from the middle of the "X" through to
the precut flap under the acoustic material.
-
Use a longer drill bit or anything sharp to punch
through from the middle of the hole to the ceiling panel.
-
Draw the cut line to the ceiling panel. Use the
sprinkler cover as a drawing guide.
-
Cut away the marked area from the ceiling panel.
Use a utility knife.
-
Remove the second precut flap from the roof. Be
careful not to tear the ceiling panel fabric around the hole.
-
Cut away the flap on the roof body cover. Use side
cutters.
-
Install the roof body cover.
-
Install the plastic trims.
-
Install the fan cover.
Figure 2. * = With optional activated carbon filter
Note:
If you are installing a sprinkler
system, follow the steps in section 6.1. If you are installing a cease fire unit,
follow the steps in section 6.2.