| Sound insulation |
| Door is leaking sound. |
Pod is not standing straight. |
Level the floor. |
| Door is too low. |
Adjust the door height. |
| Door seal is loose. |
Reinstall the door seal |
| Door is bent outwards from the top and bottom. |
Flip the bent door upside down |
| Power issues |
| No electricity in the pod. |
Pod power cord not connected. |
Check that the pod power cord is connected to a power
outlet. |
| Pod power cord is connected to a faulty power
outlet. |
Connect the pod power cord to another power
outlet. |
| Power cord not connected to power unit. |
Check that the power cord is connected to the power unit |
| Tripped fuse. |
Reset the fuse |
| Power outlet not working. |
Power outlet cord not connected. |
Check the power outlet cord connection
|
| Fans and light |
| Fans and light do not switch on. |
Faulty motion detector. See Diagnose a faulty motion sensor. |
Contact Framery Framery support for a replacement part. |
| Loose connections. |
Check all the electrical connections |
| DC cords are disconnected. |
Check the connection between the roof module and wall module DC cords |
| Light not working. |
Light cord not connected to control unit. |
Check that the light cord is connected to the control unit |
| Light's connections are loose. |
Check the light's electrical connections (pull
out the light from the ceiling) |
| DC cords are disconnected. |
Check the connection between the roof module and wall module DC cords |
| Fans not working. |
Fan cord not connnected to control unit. |
Check that the fan cord is connected to the control unit |
| Fan module's connections are loose. |
Check the fan module's electrical connections |
| DC cords are disconnected. |
Check the connection between the roof module and wall module DC cords |
| Ventilation is at maximum level all the time. |
DC cord is broken. |
Contact Framery Framery support for a replacement part. |
| Noisy fans. |
Fan blades are obstructed. |
Check that fan blades can move freely. |
| Fan speed set to 100%. |
Adjust the fan speed |
| Air inside the pod is not fresh. |
Pod is positioned in direct sunlight, under a heating duct, or close
to some other heat source. Or, there is not enough space around or above
the pod. See Operating space. |
Move the pod to another location. |