| Sound insulation |
| Pod is leaking sound. |
A gap between back glasses. |
Push the back glasses together. |
| The seal between the frontside glasses and
frames is too short. |
Stretch the old seal and reinstall
it. |
| There is a gap under the door. |
If the seals have been cut too short, replace
them. Adjust the automatic door
seal. |
| Pod is not standing straight. |
Straighten the pod. |
| The acoustic panel is folded under the roof
cover panels. |
Check that the acoustic panels are
straight. |
| Door |
| Door is difficult to
close. |
The seals are installed on the
wrong side of the front glasses. |
Remove the seals and install them on the
inside of the pod. |
| The side frame seals and the
floor or ceiling threshold seal overlap. |
Cut the side frame seal to the correct
length. |
| No adjustment plate under the
lower hinge. |
Install an adjustment plate under the lower
hinge. |
| The automatic seal descends too early. |
Adjust the automatic door seal. |
| Pod is not standing straight. |
Straighten the pod. |
| Power issues |
| No electricity in
the pod. |
Pod power cord not
connected. |
Check that the pod power cord is
connected to a power outlet. |
| Pod power cord is connected to a
faulty power outlet. |
Connect the pod power cord to
another power outlet. |
| One or more electrical
connections are disconnected. |
Check that all electrical connections are
secure. |
| ON/OFF switch of the power unitis
in the "O" position. |
Turn the ON/OFF switch of the power unit in
the "I" position. |
| Power outlet not working. |
Power outlet cord not is
connected. |
Connect the power outlet cord. |
| Fans and light |
| Fans and light do not switch
on. |
Faulty motion detector. See Diagnose a faulty motion detector. |
Contact Framery support for a replacement
part. |
| The electrical connections were installed in
the wrong order during installation and with the main power cord
connected. |
Disconnect the power cord and reconnect
it. |
| One or more connections to the control unit
are disconnected. |
Check that all the connections to the control
unit are secure. |
| One or more electrical connections (power
column, roof, under the sofa) are disconnected. |
Check that all the electrical connections are
secure. |
| The converter that supplies power to the
control unit is broken. |
Contact Framery support for a replacement
part. |
| Light not working. |
Light cord not connected to control
unit. |
Check that the light cords are connected to
the control unit. |
| Light's connections are loose. |
Check that all the electrical connections are
secure |
| DC cords are disconnected. |
Connect the DC cords. |
| Fans not working. |
Fan cord not connected to control
unit. |
Check that the fan cords are connected to the
control unit. |
| Fan module's connections are loose. |
Check that all the electrical connections are
secure |
| DC cords are disconnected. |
Connect the DC cords |
| One or more fans are at maximum level all the
time. |
DC cord of the fan is broken. |
Contact Framery support for a replacement
part. |
| Noisy fans. |
Fan blades are obstructed. |
Check that fan blades can move
freely. |
| Fan speed set to 100%. |
Reduce the fan speed |
| The pod is improperly positioned. |
If possible, move the pod. |
| Air inside the pod is not
fresh. |
The ventilation channels are dirty. |
Clean the ventilation channels. |
| The fans do not work. |
Check that the electrical connections of the
fan modules are secure. |
|
Check that the fan cords are connected to the
control unit. |
| The setting on the control unit for the fan
speed and light is not optimal. |
Adjust the settings from the control
unit. |