Install the fire alarm
Note: The installation area is approx. 150
mm (6 in) from the rear ABS strip towards the front of the pod at the straight portion of
the ceiling felt.
Note: The maximum recommended screw size is 5x25 mm.
If you intend to install a wired alarm, follow these instructions.
-
Remove the roof body covers.
-
Remove the light.
-
Cut a notch in the ceiling felt. Use a utility knife.
-
Install the fire alarm with 5x25 screws through the ceiling felt.
-
Guide the electrical wiring for the fire alarm under the light and through the notch in
the roof.
Note: Make sure that the wiring can move freely and that it is not stuck between the edge of the light and the ceiling felt.
-
Guide the electrical wiring out of the notch in the roof.
-
Reinstall the light.
-
Cut a notch in the roof body cover for the electrical wiring.
-
Reinstall the roof body covers.
Note: Make sure the electrical wiring is not damaged during the installation.