Remove the table (2Q Standard)
-
Disconnect the HDMI cord and the power cord from the display.
-
Remove the duct cover.
-
Disconnect power outlet cord from the GST extension cord.
-
Pull the HDMI cord out of the power column.
-
Disconnect the optional LAN cord from the power socket.
-
Remove the screws from the angle irons in the power column.
-
Lift the table out of the pod.