Troubleshooting

Issue Cause Solution
DOOR
Door is leaking sound Door is sagging Straighten the door
Gap between the door and bottom threshold Straighten the door
Lock latch is stuck Lock latch screws fastened too tight Loosen the handle screws
Door does not close properly Uneven office floor Check the floor level and move the pod to a new location
Threshold is installed the wrong way around Reinstall the threshold correctly
Door does not close by itself Hinges are not loaded Load the hinges
SOUND INSULATION
Pod is leaking sound A gap between the back glasses Tighten the back glasses
Pod is leaking sound The upper door gasket is not installed Install the upper door gasket
Door is leaking sound Door is sagging Straighten the door
Gap between the door and bottom threshold Straighten the door
ELECTRICS
The presence sensor does not work Cables are blocking the core unit Move the blocking cables
No electricity in the pod Pod power cord is not connected Check that the pod power cord is connected to a working power outlet
Pod power cord is connected to a faulty power outlet Connect the pod power cord to another power outlet
Internal power cord connections are loose Check the power cord connection to power unit
24V cable is not connected to the power unit Connect the 24V cable to the power unit
No electricity in the power outlet inside the pod Cable connections are loose or not connected Check the connections in the power unit and under the table
Touchscreen is not working (black screen) HDMI cable is not connected to the touchscreen or the cable is loose Check that the HDMI cable is connected to the touchscreen and core unit and reboot the pod
Touchscreen is not responsive HDMI cable might be faulty Test with a new HDMI cable, if this does not help, contact Framery support
Lights are not working

The presence sensor does not work properly
Cables are blocking the core unit

Install the cables properly
Fan is not working Fan cables not connected properly Install the cables properly
Touchscreen / lights / fan not working as expected Wrong pod type selected Change the pod type
Other half of the pod is not working Radar and core units are not connected Connect the cable 5.0
Other half of the pod is not working Power units are not connected together Connect the power units
FURNITURE & INTERIOR
Light is hanging Cables are obstructing the light base Reinstall the lights
EXTERIOR
The occupancy lights are not flush Occupancy lights installed incorrectly Reinstall the occupancy lights
Roof exterior panels do not fit Speaker cutout is not removed from the panel Remove the cutout from the roof exterior panel
Bottom exterior panels are bulging / sagging Panels are not on top of the plastic holders Install the panels correctly