Troubleshooting
| Issue | Cause | Solution |
|---|---|---|
| DOOR | ||
| Door is leaking sound | Door is sagging | Straighten the door |
| Gap between the door and bottom threshold | Straighten the door | |
| Lock latch is stuck | Lock latch screws fastened too tight | Loosen the handle screws |
| Door does not close properly | Uneven office floor | Check the floor level and move the pod to a new location |
| Threshold is installed the wrong way around | Reinstall the threshold correctly | |
| Door does not close by itself | Hinges are not loaded | Load the hinges |
| SOUND INSULATION | ||
| Pod is leaking sound | A gap between the back glasses | Tighten the back glasses |
| Pod is leaking sound | The upper door gasket is not installed | Install the upper door gasket |
| Door is leaking sound | Door is sagging | Straighten the door |
| Gap between the door and bottom threshold | Straighten the door | |
| ELECTRICS | ||
| The presence sensor does not work | Cables are blocking the core unit | Move the blocking cables |
| No electricity in the pod | Pod power cord is not connected | Check that the pod power cord is connected to a working power outlet |
| Pod power cord is connected to a faulty power outlet | Connect the pod power cord to another power outlet | |
| Internal power cord connections are loose | Check the power cord connection to power unit | |
| 24V cable is not connected to the power unit | Connect the 24V cable to the power unit | |
| No electricity in the power outlet inside the pod | Cable connections are loose or not connected | Check the connections in the power unit and under the table |
| Touchscreen is not working (black screen) | HDMI cable is not connected to the touchscreen or the cable is loose | Check that the HDMI cable is connected to the touchscreen and core unit and reboot the pod |
| Touchscreen is not responsive | HDMI cable might be faulty | Test with a new HDMI cable, if this does not help, contact Framery support |
| Lights are not working |
The presence sensor does not work properly |
Install the cables properly |
| Fan is not working | Fan cables not connected properly | Install the cables properly |
| Touchscreen / lights / fan not working as expected | Wrong pod type selected | Change the pod type |
| Other half of the pod is not working | Radar and core units are not connected | Connect the cable 5.0 |
| Other half of the pod is not working | Power units are not connected together | Connect the power units |
| FURNITURE & INTERIOR | ||
| Light is hanging | Cables are obstructing the light base | Reinstall the lights |
| EXTERIOR | ||
| The occupancy lights are not flush | Occupancy lights installed incorrectly | Reinstall the occupancy lights |
| Roof exterior panels do not fit | Speaker cutout is not removed from the panel | Remove the cutout from the roof exterior panel |
| Bottom exterior panels are bulging / sagging | Panels are not on top of the plastic holders | Install the panels correctly |